Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 8103, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081825

RESUMO

Autonomous migration is essential for the function of immune cells such as neutrophils and plays an important role in numerous diseases. The ability to routinely measure or target it would offer a wealth of clinical applications. Video microscopy of live cells is ideal for migration analysis, but cannot be performed at sufficiently high-throughput (HT). Here we introduce ComplexEye, an array microscope with 16 independent aberration-corrected glass lenses spaced at the pitch of a 96-well plate to produce high-resolution movies of migrating cells. With the system, we enable HT migration analysis of immune cells in 96- and 384-well plates with very energy-efficient performance. We demonstrate that the system can measure multiple clinical samples simultaneously. Furthermore, we screen 1000 compounds and identify 17 modifiers of migration in human neutrophils in just 4 days, a task that requires 60-times longer with a conventional video microscope. ComplexEye thus opens the field of phenotypic HT migration screens and enables routine migration analysis for the clinical setting.


Assuntos
Cristalino , Lentes , Humanos , Microscopia , Microscopia de Vídeo , Movimento Celular
2.
Biomed Eng Online ; 20(1): 102, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34641889

RESUMO

BACKGROUND: Retinal degenerative diseases, e.g., retinitis pigmentosa, cause a severe decline of the visual function up to blindness. Treatment still remains difficult; however, implantation of retinal prostheses can help restoring vision. In this study, the biocompatibility and surgical feasibility of a newly developed epiretinal stimulator (OPTO-EPIRET) was investigated. The previously developed implant was extended by an integrated circuit-based optical capturing, which will enable the immediate conversion of the visual field into stimulation patterns to stimulate retinal ganglion cells. RESULTS: The biocompatibility of the OPTO-EPIRET was investigated in vitro using the two different cell lines L-929 and R28. Direct and indirect contact were analyzed in terms of cell proliferation, cell viability, and gene expression. The surgical feasibility was initially tested by implanting the OPTO-EPIRET in cadaveric rabbit eyes. Afterwards, inactive devices were implanted in six rabbits for feasibility and biocompatibility testings in vivo. In follow-up controls (1-12 weeks post-surgery), the eyes were examined using fundoscopy and optical coherence tomography. After finalization, histological examination was performed to analyze the retinal structure. Regarding the in vitro biocompatibility, no significant influence on cell viability was detected (L929: < 1.3% dead cells; R-28: < 0.8% dead cells). The surgery, which comprised phacoemulsification, vitrectomy, and implantation of the OPTO-EPIRET through a 9-10 mm corneal incision, was successfully established. The implant was fixated with a retinal tack. Vitreal hemorrhage or retinal tearing occurred as main adverse effects. Transitional corneal edema caused difficulties in post-surgical imaging. CONCLUSIONS: The OPTO-EPIRET stimulator showed a good biocompatibility profile in vitro. Furthermore, the implantation surgery was shown to be feasible. However, further design optimization steps are necessary to avoid intra- and postoperative complications. Overall, the OPTO-EPIRET will allow for a wide visual field and good visual acuity due to a high density of electrodes in the central retina.


Assuntos
Retinite Pigmentosa , Próteses Visuais , Animais , Eletrodos Implantados , Implantação de Prótese , Coelhos , Retina , Retinite Pigmentosa/cirurgia
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 246-249, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29059856

RESUMO

There are several previously published approaches of measuring local pulse transit time (PTT). One of these approaches is to use two optical sensors based on photoplethysmography (PPG). However, little information about reproducibility in PPG based PTT measurement is available. Therefore, we performed a small sample size study (n = 5) to investigate quantitative criteria for reproducible PTT measurement. The inflection point as a characteristic feature of the pulse wave showed the most stabile results under varying conditions. Furthermore, we found that correlation between related pulse waves could be used as a threshold for signal quality. We suggest to implement a real-time operator feedback based on the found criteria to ensure reproducible PTT measurements.


Assuntos
Fotopletismografia , Pressão Sanguínea , Frequência Cardíaca , Pulso Arterial , Análise de Onda de Pulso , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...